LDC-X200 Laser Wires Rods Diameter Measuring System Inquiries(0) Tags:wires Rods Diameter Measuring Price: US $5000.001-100 Quantity: piece Total price:US $0.00 (Excluding shipping cost) Add to Inquiry Cart Add to Wish List (0 Adds) Ship From: Other city Support Payment Terms: T/T,L/C,D/P,D/A Wuhan CenterRise M&C Engineering CO., Ltd. 2022 Registered

Hubei, China. This supplier has been open since 2007

Business Type: Factory/Manufacturer Main Products: breakout prediction system, ladle slag detection system, mold expert system, continuous casting billet detection system, roll gap measuring instrument system, ladle thickness measurement system, etc. Seller Homepage
    Contact Info
  • 13995588597
  • 8613995588597
  • 1942278616@qq.com
  • sales@whzfy.com
  • 13995588597
  • sales@whzfy.com
  • 15727288019
  • Building 4, Hengxin Industrial Park, No. 8 Xinhua Avenue, Huangpi District, Wuhan, Hubei, China
  • https://whzfy18.com
Top Selling Products From This Seller
Handheld Thermocouple Calibrator US $500.00 / pieceInquiries(0)
BPS-K600 Mould Breakout Prediction System US $5000.00 / pieceInquiries(0)
LAG-S200 Ladle Slag Detection System (Vibration Type) US $5000.00 / pieceInquiries(0)
Product Details
Feedback(0)
Report/ Claim
Item Specifications
  • function:Wires Rods Diameter Measuring System
Product Description

LDC-X200 Laser Diameter Measurement System


Overview

The non-contact diameter measuring system, is mainly used in the measurement of the outer diameter of various wire rods, bars, wires and pipes. The system can detect the change of the diameter (outer diameter) of the measured object in real time under the high temperature state.


The working principle

The diameter measuring system takes the laser scanning method as an example. It adopts the probe imported from Japan, which can achieve an accuracy of plus or minus 2 microns in the range of 0.3 to 30 mm. The acquisition frequency reaches 2000 times/second. The probe uses a self-excited infrared light source, which overcomes the measurement problem in dim environments.

It adopts the measurement method of pulse parallel light scanning, and has a strong ability to resist the jitter of the measured object. (As shown in Figure 1) Since the shaking frequency of the measured object is much smaller than the scanning frequency, when the measured object A moves in the shakeable area, the measurement result will be able to ensure its accuracy because the time it blocks the beam does not change.

Figure 1: Probe Scanning Radiation Area


The detection principle is as follows

Figure 2: Working Principle


First, the mold oscillator generates self-excited high-frequency pulses, which are sent to the comparator and the stepping servo motor respectively. The stepping servo motor drives the octahedral prism to rotate at a high speed, and reflects the infrared laser emitted by the laser generator to the convex lens A. It becomes parallel light, and then collects on the photosensitive element C through the convex lens B in the infrared receiving probe. The photosensitive element C converts this signal into a corresponding electrical signal and sends it to the other end of the comparator to compare with the original signal.

When there is no object to be measured in the measuring probe, the pulse signal at both ends of the comparator will be the same. Therefore, there is no difference output: when there is an object to be measured in the measuring probe, the photosensitive element C will output no pulse signal during the period of scanning through the object to be measured. Therefore, there will be a difference input for a period of time at both ends of the comparator, which corresponds to the diameter of the measured object. By calculating the oscillation period of the pulse and the length of the time slice without pulse, the diameter of the measured object can be known.


The composition and functions of the system

The system consists of the following main parts (as shown in Figure 1)

1. A measurement frame with four pairs of high-frequency laser scanning probes and non-contact infrared thermometers is installed

2. Four intelligent signal processors connected with four pairs of high frequency laser scanning probes

3. Cold air blowing system for cooling and cleaning the measuring frame

4. High-performance intelligent controller responsible for front-end data signal processing and network communication

5. Data processing and analysis system installed with industrial grade PC, monitor and printer


The technical indexes

Feedback(0)
Not Available
Feedback(0)
Not Available
More Products
LDT-L200 Ladle Lining Laser Thickness GaugeUS $5000.00 / piece Inquiries(0)
Mold Surface Cladding Detection EquipmentUS $100000.00 / piece Inquiries(0)
BPS-K600 Mould Breakout Prediction SystemUS $5000.00 / piece Inquiries(0)
LAG-S400 Infrared Converter Slag Detection SystemUS $5000.00 / piece Inquiries(0)
Ladle Comprehensive Management SystemUS $100000.00 / piece Inquiries(0)
Laser Mold Taper Measuring InstrumentUS $100000.00 / piece Inquiries(0)
SPD-V020 Multifunctional Strand Condition MonitorUS $5000.00 / piece Inquiries(0)
Handheld Thermocouple CalibratorUS $500.00 / piece Inquiries(0)
Analog Heat Source InstrumentUS $100000.00 / piece Inquiries(0)
MAC-G320 Automatic Mold Flux Feeding MachineUS $5000.00 / piece Inquiries(0)